[Highlight Automatic Adj.]
Overview
Use the scanner to change the gamma curve. The gradation and background density of the highlighted part will be adjusted automatically.
Adjust if the gradation density reproduction of the highlighted part differs for each screen.
- The following setting is required to use this function.
- Perform [Gamma Automatic Adj.].
- The procedure for making adjustments varies depending on the options installed.
- Normally, adjustment is done using [Highlight Automatic Adj.]. Use [Highlight Adjustment] to make fine tuning.
- Use white printing paper for this adjustment. If there is color on the paper, the color of the chart changes depending on that color, and the adjustment cannot be made correctly.
- For details about [Gamma Automatic Adj.], refer to [Adjustment / Maintenance].
Specifications
| Print Workflow, Adjustment / Maintenance |
| | |
| |
| |
| |
| |
| | |
| Resets the highlight gradation value on the displayed screen to zero. Once this option is pressed, a dialog box will appear. Press [Yes] to reset. |
| Switches the screen to be adjusted. |
|
| Prints the chart to be used for measurement. |
| Re-adjusts. Press [Yes] when the confirmation dialog box is displayed. |
| Moves to the previous screen. |
| |
| |
| Control panel - Utility/Counter - [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Highlight Automatic Adj.] |
Procedure
This section details the procedure for when neither Intelligent Quality Optimizer IQ-501 or Relay Unit RU-518m are installed.
The chart will be automatically measured if either of Intelligent Quality Optimizer IQ-501 or Relay Unit RU-518m is installed. In such a case, you can stop after Procedure 6.
The contents of the chart to be output may differ.
1
Press [Next] or [Previous] to select a screen to be adjusted.
2
Press [Reset Adj. Data] if the gradations of the image highlighted part is over-exposed or under-exposed.
This will reset the highlight value to zero.
3
Press [Readjust].
Press [Yes] when the confirmation dialog box is displayed.
5
Set A4 v paper and select the relevant paper feed tray.
6
Press Start on the Control panel.
A chart is output.
7
Place the output test chart on the
Original glass.
Set the triangle mark [2] on the chart [1] to the left and the print side facing down.
Move and touch chart [1] firmly against the vertical direction document size index [3] and horizontal direction document size index [4], and set to Original glass.
8
Place around 10 sheets of white paper on top of the chart and close ADF.
9
Press [Start] or Start on Control panel.
[Current Data] of [Y], [M], [C] and [K] is updated.
10
Repeat procedure 4 through 9 until [Completed normally] is displayed.
- [Completed normally] message will not display because the results of the 1st scanning do not determine whether the adjustment value is good or bad. Repeat Steps 4 through 9 until [Completed normally] is displayed.
- If Error Code 1, 2 or 10 is displayed, check whether the chart is positioned correctly. If any other error code is displayed, contact your service provider.