Collectively adjust items related to image stability. You can configure the settings so that the adjustment items are selected automatically.
Press [Package Color Auto Adj.].
For details about the procedure, refer to [Package Color Auto Adj.].
Before performing the adjustment, press [Initial Set.] as necessary to enable the adjustment settings to be changed.
Put a check mark in the [Auto Selection] check box of [Additional Adjustment].
Execute [Image Diagnosis] in [Auto Selection], and adjust those items that can be executed, excluding controller calibrations such as [Exact Color] and [G7].
Use the paper in the maximum density adjustment tray. Load the paper used when registering target density with a width of 279.4 mm or more, and a length of 420.0 mm to 487.7 mm, into the tray.
If [Use Color Density Control] is set to [OFF] in [Basic Setting] of [Color Density], the [Auto Selection] adjustment item is not included. Load the paper used when registering the target density into the maximum density adjustment tray.
To perform [Auto Selection], set [Screen1] or [Screen2] of [Custom Screen] to [Dot190]. For details about configuring [Custom Screen], refer to Screen.
Change any of the setting contents ([Screen of Adjustment Target], [Additional Adjustment], [Maximum Density Adjustment Tray], [Adjustment Tray]).
Load the paper used when registering the target density into the tray, and select that tray.
You can also change the [Paper Setting] and [Output Setting].
Press [Start].
A simple image analysis chart and a basic image diagnosis chart are output.
If [DetailedDiagnosis/Sync.SimpleDiagnosis] is set to [ON] in [Basic Setting] of [Image Diagnosis], [Detailed Diagnosis] is performed automatically if the diagnosis shows any issues. A detailed diagnosis chart is output if this happens.
If [DetailedDiagnosis/Sync.SimpleDiagnosis] linked to the simple diagnosis is set to [OFF] in [Basic Setting] of [Image Diagnosis], the results of the [Simple Diagnosis] are displayed. Select [Detailed Diagnosis] when there are items for which detailed diagnosis recommendations are displayed in the results of the diagnosis.
For details about [Image Diagnosis], refer to What Is [Image Diagnosis]?.
Check the contents of the adjustment results displayed after the adjustment has been completed.