Target option: Intelligent Quality Optimizer IQ-501
If a rounding error occurs, the image position is misaligned by 1 pt (approximately 0.35 mm / 0.013").
In this case, the original image position is also misaligned, so this misalignment cannot be adjusted using the [Auto Image Adjustment] function of Intelligent Quality Optimizer IQ-501.
Work Time: 10 mins
This problem can be resolved by setting [Image Shift] in the printer driver or AccurioPro Print Manager.
A misalignment between the front and back positions occurs for several reasons. Check whether the paper used for both sides adjustment is cut correctly.
[AutoMeasure] allows you to collectively adjust multiple paper trays, or output multiple charts to enhance the adjustment accuracy.
In case of AccurioPro Print Manager, open the [Job Settings...] of the job.
It is recommended that you shift the front side by 1 pt (approximately 0.35 mm / 0.013") in the paper feed direction.