Cause | The unit is converted from mm or inch to pt in RIP processing of the EFI controller. At this time, a rounding error may occur because the number is indivisible. If a rounding error occurs, the image position is misaligned by 1 pt (approximately 0.35 mm / 0.013"). If this problem occurs, the original image position is also misaligned, so this misalignment cannot be adjusted using the [Auto Image Adjustment] function of Intelligent Quality Optimizer IQ-501. |
Option | Intelligent Quality Optimizer IQ-501, EFI controllers |
Working time | 10 minutes |
Overview | This problem can be resolved by setting [Image Shift] in the printer driver or Command WorkStation (CWS). |
Precautions | A misalignment between the front and back positions occur for several reasons. Check whether the paper used for both sides adjustment is cut correctly. |
Procedure | The following procedure shows an example for the Fiery color server. 1. When Intelligent Quality Optimizer IQ-501 is mounted, select [MACHINE] - [Paper Setting] - [Both Sides Adj.] - [AutoMeasure] on the Touch panel. 2. Correct the misalignment between image positions for each paper tray. [AutoMeasure] allows you to collectively adjust multiple paper trays, or output multiple charts to enhance the adjustment accuracy. 3. Open [Properties] of the job in the printer driver or Command WorkStation (CWS). 4. Set the shift amount in [Image Shift]. It is recommended that you shift the front side by 1 pt (approximately 0.35 mm / 0.013") in the paper feed direction. |
Was this information useful?