Administrator Setting: Common Setting

The following features can be provided by switching the selection. This setting can also be performed by selecting Common Setting from the User Setting.

Menu item

Description

Setting value (: Default)

One Shot Message Indication Time

Select the time span to display a shot message, such as Original size is A4, in the message area of the touch panel.

3 seconds, 5 seconds

Offset by Job Unit

Specify whether or not to offset the output sheets by job.

ON, OFF

Also specify the number of jobs to be offset when selecting ON for this function (default: 0001).

Continuation Print

Specify whether or not to output multiple reserve jobs in succession without stopping the machine at a job break.

Copy ON, Copy OFF, Printer ON, Printer OFF

Dark Tone Control

In order to adjust the quality of output image, select whether to automatically decrease the copying speed (Quality), prioritize the copying speed, or disable the control over the tone.

OFF, Quality, Performance

Icon Display for Dark Tone Control

Select whether or not to display the Dark Tone icon while the Dark Tone Control function is enabled.

This function is available only when Quality or Performance is selected at Dark Tone Control.

ON, OFF

Dash Length(Page Stamp)

Select the length of the dash to be used in a style of Page No. in Stamp.

Long, Short

Center Crop Mark Trim Margin

Specify the space between the center crop mark and image area (center crop mark trim margin).

0.0 mm to 20.0 mm (Default: 1.0)

Schedule Cross Axis Unit (Default)

Select the unit of horizontal axis on the Schedule screen.

Timetable, Time Frame (m), Sheet Volume

Hold Job Status after Output (Default)

Select the default value to delete or save the data of hold job after outputting.

Delete, Save

Hold Job Direct Output (Default)

Select the default for the Direct Output check box under the Hold Job screen.

ON selects the check box, and OFF clears the check box.

After the change, turn OFF/ON the power switch to apply the setting.

ON, OFF

Offset Output Mode

Specify how to offset the output sets.

Change Out Pos., Stop Print, Change Out Pos. + Partition Paper (Tray1, Tray2, Tray3, Tray4, Tray5, Tray6, Tray7, Tray8, Tray9, Tray10, Tray11, PI1, PI2, PI-PFU1, PI-PFU2, PI-PFU3), Partition Paper (Tray1, Tray2, Tray3, Tray4, Tray5, Tray6, Tray7, Tray8, Tray9, Tray10, Tray11, PI1, PI2, PI-PFU1, PI-PFU2, PI-PFU3)

Needless Tab Paper Exit

Specify whether or not to automatically discharge the oddments of tabbed sheets loaded in a tray as a set for copy job.

ON, OFF

Remaining Memory (Measurement Unit)

Select the unit of displaying the remaining memory.

%, GB

Remaining Memory (Warning)

Select the percentage at which to give warning when the remaining memory is low.

5% or Less, 10% or Less

[Proof Copy] 1 Set/1st Sheet Selection

If it is turned ON, the confirmation window is opened and you are asked to output one confirmation copy or to output only its first page when the Proof Copy is pressed.

ON, OFF

Temp. Down/Up Control before Print

Select whether to rotate the fusing roller before printing starts, in order to print at the appropriate temperature.

ON, OFF

Both Sides Rotate/Skew

If Disable is selected, the Rotate/Skew adjustment does not become available and does not function.

Enable, Disable

Stop when Water Tank Near Empty

Select whether to temporarily stop a job when the humidifier tank runs low on water.

Temporary Stop, Not Temporary Stop

Auto Image Adjustment Deviation Check

Select whether to automatically check a deviation. If you select ON, enter the specified value of a deviation.

This option is displayed when Intelligent Quality Optimizer IQ-501 is mounted on the machine.

ON (ON: 0.5 mm to 10.0 mm), OFF

Operation after Deviation Detected

Select an operation to be performed when a deviation is detected. When Continue Output is selected, specify the paper tray to feed partition paper and the number of detection times.

This option is displayed when Intelligent Quality Optimizer IQ-501 is mounted on the machine.

Stop, Continue Output, Partition Paper (Tray1, Tray2, Tray3, Tray4, Tray5, Tray6, Tray7, Tray8, Tray9, Tray10, Tray11), Detection Count (2 to 10 times)

Select Chart Type (Auto Image Adj.)

Select an automatic image adjustment chart for each paper weight. The unit of weight can be switched.

This option is displayed when Intelligent Quality Optimizer IQ-501 is mounted on the machine.

40-49g/m2/10-13 lb Bond: Type1, Type2

50-54g/m2/14-15 lb Bond: Type1, Type2

55-61g/m2/16-17 lb Bond: Type1, Type2

62-74g/m2/18-19 lb Bond: Type1, Type2

75-80g/m2/20-21 lb Bond: Type1, Type2

81-91g/m2/22-24 lb Bond: Type1, Type2

92-105g/m2/25-28 lb Bond: Type1, Type2

106-135g/m2/29-36 lb Bond: Type1, Type2

136-162g/m2/37-43 lb Bond: Type1, Type2

163-216g/m2/44-57 lb Bond: Type1, Type2

217-256g/m2/58-68 lb Bond: Type1, Type2

257-300g/m2/69-81 lb Bond: Type1, Type2

301-350g/m2/82-93 lb Bond: Type1, Type2

Change Unit

  1. Follow the procedure on Displaying the [Administrator Setting Menu] Screen to display the Administrator Setting Menu screen.

  2. Press Common Setting on the Administrator Setting Menu screen.

    The Common Setting screen is displayed.

    • supplementary explanationFor subsequent operations, follow the same procedure as that in User Setting - Common Setting. Refer to [User Setting]: [Common Setting] for details.