Regular adjustment flow: High Precision

In addition to Regular adjustment flow: Normal, perform this adjustment especially in the following cases:

  • Just before outputting a job based on the strict density standard

  • When the density stability is not desirable (you want to increase the accuracy of reproducibility)

  • When the paper type is different

  • If you use Package Color Auto Adj., this machine automatically makes the adjustments in step 2 below and after.
    To use the function, install Intelligent Quality Optimizer IQ-501. For details, refer to [Package Color Auto Adj.].

Color Density Control

Confirm whether the Periodical Adj. Execution of Basic Setting is set to ON.

Color Density Control: Basic Setting

In Color Density in Paper Setting, check if Default Adj. Data or Registered Adj. Data is selected for the tray.

Applying the registered adjusted color density to the machine

To use general paper, select Default Adj. Data.

To use special paper or increase the accuracy of the automatic adjustment, Each Paper Type Color Adj. is recommended. For details, refer to Color Density Control: Each Paper Type Color Adjustment.

Gamma Automatic Adjustment

This automatically adjusts the density reproducibility of the whole paper to be output.

[Gamma Automatic Adj.]

Maximum Density Adjustment

Increase the accuracy of reproducibility of density.

[Maximum Density Adjustment]

Color Density Control

Perform Color Density Manual Control.

Color Density Control: Color Density Manual Control